lamp does not respond to any command The lamp recalls the scenarios but does not respond to the "arrows" and +/- commands When you press one of the arrow keys, the lamp does not move or stops after a few seconds You cannot stop the timed recall of scenarios The lamp makes mechanical noises I have two or more Anellum lamps but I cannot program them individually, when I press the arrow keys, they all move at the same time I have two or more Anellum lamps and they have different ID numbers but I can’t program them all I have several Anellum lamps assembled in different rooms and the remote control of one room operates the lamps installed in another room of the apartment I have trouble activating functions that entail pressing more than one key in sequence recall of the scenarios is interrupted after a few hours When I insert the plug of the lamp in the power outlet, the Anellum lamp moves on its own for about 20 seconds and does not respond to any command What happens when there is a black-out? Can I assemble an Anellum lamp on the wall or ceiling?

The lamp does not respond to any command

Make sure that the Anellum lamp is correctly connected to the power outlet.
Check that the LED on the remote control lights up when you press the keys, and if it doesn’t, check that the batteries are charged.
Check that the remote control transmits on the channel set on the lamp:

  • view the channel of the lamp by pressing SHIFT and then LUM+ and LUM- simultaneously for about 3 seconds.
  • Set the channel on the remote control
Check that timed recall of the scenarios is not set and, if it is, press the "OFF" key to return to normal mode
top^

The lamp recalls the scenarios but does not respond to the "arrows" and +/- commands

The remote control is not addressing the lamp you want to program:

  • recall it by pressing the LMP+ key repeatedly until the Anellum lamp blinks once
or
  • view the ID number of the lamp by pressing SHIFT and then LMP+ and LMP- simultaneously for about 3 seconds
  • recall the lamp directly
top^

When you press one of the arrow keys, the lamp does not move or stops after a few seconds

This is normal, you have probably reached the travel end, so press the other arrow key

top^

The lamp makes mechanical noises

It is normal that the lamp makes soft mechanical noises under some conditions

top^

You cannot stop the timed recall of scenarios

You must press the "OFF" key to return to normal mode

top^

I have two or more Anellum lamps but I cannot program them individually, when I press the arrow keys, they all move at the same time

You must assign the lamps different ID numbers

top^

I have two or more Anellum lamps and they have different ID numbers but I can’t program them all

Check that you have carried out the “setting up the remote control” procedure correctly

top^

I have several Anellum lamps assembled in different rooms and the remote control of one room operates the lamps installed in another room of the apartment

You must assign the Anellum lamps a different transmission channel for each room

top^

I have trouble activating functions that entail pressing more than one key in sequence

Take care to follow carefully the instructions which tell you to press the keys "in sequence" or simultaneously.
In a key sequence, you must not let more than 2 seconds pass between pressing one key and the next

top^

Timed recall of the scenarios is interrupted after a few hours

This is normal, timed recall terminates automatically after 8 hours

top^

When I insert the plug of the lamp in the power outlet, the Anellum lamp moves on its own for about 20 seconds and does not respond to any command

This is normal, the Anellum lamp is executing its initialization routine, a procedure that is indispensable for the correct functioning of the lamp

top^

What happens when there is a black-out?

When power is restored, the Muvis lamps present in the apartment will execute the initialization routine and will remain off

top^

Can I assemble an Anellum lamp on the wall or ceiling?

The Anellum lamp is designed to be mounted in these positions but you will need a bracket which you must purchase separately. Remember that wall or ceiling installation mist be executed by specialized staff.